Incident No. NCR-2024-00065

Incident No.NCR-2024-00065
Incident Date06/19/2024
Item Part No.CSNDX288F043
Item Part Description

PORTED SLEEVE FOR NON ELASTOMERIC, SLIDING SLEEVE DOWN TO OPEN MATERIAL : AISI 4140, 18-22 HRC OR EQ. TO L-80

Quantity0
Drawing No.CSNDX288F043
JO NO.J2405-0083
PO/SO. NO.Not Mentioned
GRN/OR/CR No.Not Mentioned
OperationCNC TURNING PROCESS- 05 & 06
Created ByQC
Created Date06/19/2024
TitleNCR-24-0022 (Inprocess inspection)
Incident Description

1] Thread pitch dia is more then required pitch dia.required pitch dia is 96.83496 to 97.00006 mm and observed pitch dia 97.25mm.also there is thread cut observed due t5o power cut. 2] Groove position is shift 5.15mm on upward direction. required groove distance from face is 61.97mm and observed 56.97mm.photo's is also attached.

StandardNot Mentioned
ReferenceNot Mentioned
User loginemployee
TypeIn-house
Supplier / Customer Name
Disposition
Justification
Upload Document
  • Upload Document
  • Upload Document
  • Upload Document
  • Upload Document
  • Upload Document
Unique ID70aa8