Incident No. | NCR-2024-00065 |
---|---|
Incident Date | 06/19/2024 |
Item Part No. | CSNDX288F043 |
Item Part Description | PORTED SLEEVE FOR NON ELASTOMERIC, SLIDING SLEEVE DOWN TO OPEN MATERIAL : AISI 4140, 18-22 HRC OR EQ. TO L-80 |
Quantity | 0 |
Drawing No. | CSNDX288F043 |
JO NO. | J2405-0083 |
PO/SO. NO. | Not Mentioned |
GRN/OR/CR No. | Not Mentioned |
Operation | CNC TURNING PROCESS- 05 & 06 |
Created By | QC |
Created Date | 06/19/2024 |
Title | NCR-24-0022 (Inprocess inspection) |
Incident Description | 1] Thread pitch dia is more then required pitch dia.required pitch dia is 96.83496 to 97.00006 mm and observed pitch dia 97.25mm.also there is thread cut observed due t5o power cut. 2] Groove position is shift 5.15mm on upward direction. required groove distance from face is 61.97mm and observed 56.97mm.photo's is also attached. |
Standard | Not Mentioned |
Reference | Not Mentioned |
User login | employee |
Type | In-house |
Supplier / Customer Name | |
Disposition | |
Justification | |
Upload Document | |
Unique ID | 70aa8 |